== List of things following DigiOS beam time ==
== List of things following DigiOS beam time ==
- Lots of GUI mods (need itemized list)


- Check VME Crate 2
March 2018 -  


- Better mounts for preamp DigiOS cables
'''Trace Viewer''' - Gain understanding of the software and hardware options.


- better cabling for timing
'''File Open - Buffer Flush''' - Really becoming a bigger priority. [https://svn.inside.anl.gov/repos/dgs/Documentation/Formal/Software/ Documentation] and [https://svn.inside.anl.gov/repos/dgs/DGS1/gretClust/gretDataApp/src/ Software source]


- More adapter boards
'''UDP''' - Learn about this option more.


- rack mounted windows PC
Email for JTA - 10/2017 -  


- better data storage
Hi John, Below is a write-up of the things we discussed earlier related to the HELIOS version of the Digital DAQ. I have also tried to order them in priority as I see it. Let me know what you think and how I can help moving forward.


- faster data processing
'''Accelerator RF Readout''' - Still remains as the top priority for the daq as this would remove our analog "hack".


== Ideas Pertaining to the User Interface ==
'''Additional information / wiki write-ups''' - Basically, I know of these things, however, to use them efficiently I will need to sit down with you / Mike / etc, to understand how they work. Or, as you had mentioned, more directed write-ups on the following topics would be very useful:


Graphs are more effective than numbers for people on shifts.  Use a few graphs that summarize critical information about the current status of the experiment and data acquisition system,
- Parameters and operation of the triggering


Use as few windows as possible.  Having too many different little windows opened clutters the computer desktop and makes it difficult to find stuff.
- Parameters and operation of the throttle - DONE IN THE WIKI


The DAQ must be accessible locally (in the experimental area) and remotely.
'''Information on Pulser Usage / controls through EPICs''' - Either need to get additional windows computers to help with this or need to have a priority to input controls into EPICs.


Every experiment must have a user account. It is not good when everybody shares the same account because then you do not know who is running the active processes.
= Performance =
 
-- Understanding the triggering better
 
-- Adding in the RF Timing
 
-- How to force data to file if rates are low
 
= Increase system stability =
 
-- How to govern and automatically monitor the buffers -> ''looking into the THROTTLE variables and setup start with finding all THROTTLE variables''
/global/devel/gretTop/9-22/dgsIoc/iocBoot/iocArray/vme0X.HELIOS.cmd
load the databases, which db's hold the THROTTLE?
 
-- How to query the network / system to wake it up on startup -> ''tried to touch files but then IOC closes because files exist, also tried to ping iocX but get no response. Need to look into receiver code?''
 
-- How to reboot things remotely
 
-- Triggers / TS stop updating on the GUI (but data seems to be coming in)
 
-- Triggers / TS stop updating from one of the VMEs?
 
= Items for experimental setup/startup =
 
-- How to better use the pulser
 
-- How to get a signal out of the digitizer for use as a scope
 
= Data storage and processing =
 
-- Stability and automation for disk mounting
 
-- understand the file writing with the gtReciever (max file size etc.)
 
-- How to transfer only data that is not on the mac already
 
-- Improved way to sum up the data runs

Latest revision as of 19:03, March 14, 2018

List of things following DigiOS beam time

March 2018 -

Trace Viewer - Gain understanding of the software and hardware options.

File Open - Buffer Flush - Really becoming a bigger priority. Documentation and Software source

UDP - Learn about this option more.

Email for JTA - 10/2017 -

Hi John, Below is a write-up of the things we discussed earlier related to the HELIOS version of the Digital DAQ. I have also tried to order them in priority as I see it. Let me know what you think and how I can help moving forward.

Accelerator RF Readout - Still remains as the top priority for the daq as this would remove our analog "hack".

Additional information / wiki write-ups - Basically, I know of these things, however, to use them efficiently I will need to sit down with you / Mike / etc, to understand how they work. Or, as you had mentioned, more directed write-ups on the following topics would be very useful:

- Parameters and operation of the triggering

- Parameters and operation of the throttle - DONE IN THE WIKI

Information on Pulser Usage / controls through EPICs - Either need to get additional windows computers to help with this or need to have a priority to input controls into EPICs.

Performance

-- Understanding the triggering better

-- Adding in the RF Timing

-- How to force data to file if rates are low

Increase system stability

-- How to govern and automatically monitor the buffers -> looking into the THROTTLE variables and setup start with finding all THROTTLE variables

/global/devel/gretTop/9-22/dgsIoc/iocBoot/iocArray/vme0X.HELIOS.cmd

load the databases, which db's hold the THROTTLE?

-- How to query the network / system to wake it up on startup -> tried to touch files but then IOC closes because files exist, also tried to ping iocX but get no response. Need to look into receiver code?

-- How to reboot things remotely

-- Triggers / TS stop updating on the GUI (but data seems to be coming in)

-- Triggers / TS stop updating from one of the VMEs?

Items for experimental setup/startup

-- How to better use the pulser

-- How to get a signal out of the digitizer for use as a scope

Data storage and processing

-- Stability and automation for disk mounting

-- understand the file writing with the gtReciever (max file size etc.)

-- How to transfer only data that is not on the mac already

-- Improved way to sum up the data runs