===Throughout Gammasphere===
===Throughout Gammasphere===
[[File:CollectorBoxesLayout.png|left|800px|thumb|Figure 2. A top-view mapping of Gammasphere's collector box setup.]]
[[File:CollectorBoxesLayout.png|left|800px|thumb|Figure 2. A top-view mapping of Gammasphere's collector box setup.]]
Figure 1 shows a hemisphere of Gammasphere, and two of the collector boxes placed on it. On the other side of Gammasphere, there are another two collector boxes with the rest of the DAQ (the full picture is displayed on the [[DAQ system page]]). This is because Gammasphere has four pairs of collector boxes and VME crates (along with the power supply), each of which power and receive data from approximately 30 detectors. Figure 2 shows all of this from an above point of view; an "unfolded” drawing of how this mapping looks when viewing collectors and VME crates from their “active sides” where connections happen. Each collector box is shown (in the diagram) from the connector side, where cables are plugged in from the collector box to each [[The Slope Box Extension|SBX]] for power output. The output is accomplished using the same cable interfaces as used for the analog signal path, slow control-and-monitoring and all other detector functionality. All four collector boxes of Gammasphere are paired with their VME crate from their "active side", where the arrangement of digitizers, IOCs, and trigger modules are carefully placed. The collector boxes are labeled with the “GS#” they appear as in EPICS, with even “GS” numbers on the south hemisphere and odd “GS” numbers on the northern hemisphere. The semicircle “N” in Figure 2 represents the Gammasphere’s northern hemisphere, while “S” represents Gammasphere’s southern hemisphere. The compass directions in purple (NE, NW, SE, SW) are as in the current in-front-of-[[Argonne Gas-Filled Analyzer|AGFA]] position. The collector boxes and VME crates are flipped right-to-left when comparing East versus West because the collector boxes are rotated 180 degrees in the birds’ eye view. Note that Figure 2 is giving a closeup of the system, but Figure 1 represents what the DAQ system actually looks like in real life. Although not shown in the Figure 2 diagram, each collector box also provides a connection for hooking up the alarm and status outputs from the external 48V DC supply, so that the collector can make that data available to the control system via EPICS.  
Figure 1 shows a hemisphere of Gammasphere, and two of the collector boxes placed on it. On the other side of Gammasphere, there are another two collector boxes with the rest of the DAQ (the full picture is displayed on the [[DAQ system]] page). This is because Gammasphere has four pairs of collector boxes and VME crates (along with the power supply), each of which power and receive data from approximately 30 detectors. Figure 2 shows all of this from an above point of view; an "unfolded” drawing of how this mapping looks when viewing collectors and VME crates from their “active sides” where connections happen. Each collector box is shown (in the diagram) from the connector side, where cables are plugged in from the collector box to each [[The Slope Box Extension|SBX]] for power output. The output is accomplished using the same cable interfaces as used for the analog signal path, slow control-and-monitoring and all other detector functionality. All four collector boxes of Gammasphere are paired with their VME crate from their "active side", where the arrangement of digitizers, IOCs, and trigger modules are carefully placed. The collector boxes are labeled with the “GS#” they appear as in EPICS, with even “GS” numbers on the south hemisphere and odd “GS” numbers on the northern hemisphere. The semicircle “N” in Figure 2 represents the Gammasphere’s northern hemisphere, while “S” represents Gammasphere’s southern hemisphere. The compass directions in purple (NE, NW, SE, SW) are as in the current in-front-of-[[Argonne Gas-Filled Analyzer|AGFA]] position. The collector boxes and VME crates are flipped right-to-left when comparing East versus West because the collector boxes are rotated 180 degrees in the birds’ eye view. Note that Figure 2 is giving a closeup of the system, but Figure 1 represents what the DAQ system actually looks like in real life. Although not shown in the Figure 2 diagram, each collector box also provides a connection for hooking up the alarm and status outputs from the external 48V DC supply, so that the collector can make that data available to the control system via EPICS.  


===In Each Collector Box===
===In Each Collector Box===
[[File:CollectorBoxHardware.png|500px|thumb|Figure 3. Collector box hardware]]
[[File:CollectorBoxHardware.png|500px|thumb|Figure 3. Collector box hardware]]

Revision as of 16:58, February 17, 2023

VME CratesVME Crates
Figure 1. Black collector box on Gammasphere, circled in white; yellow-encased power supply above collector box and gray VME crate below.

As a part of Gammasphere's upgraded DAQ system, a new "collector box" has been added. The collector box collects and maps all analog signals for up to 30 detectors, coming from the pickoff card in the SBX to the collector, and being output to the digitizers. For concepts like "electric honeycomb", the collector box implements distinct hardware to accurately route signals to the digitizer. It does this this by utilizing time synchronization with its access to the trigger system to ensure that the correct set of samples are used for the reconstruction of each BGO waveform. Control and monitoring of Gammasphere's modules are maintained with the help of the collector box, using EPICS IOC. It provides power to individual SBX units via a singular 48V input from the power supply (above the circled collector box in the image to the right).

The collector box was created to replace the inefficient system that preceded it, known as VXI crates. They consisted of multiple boards and racks, including over a hundred heavy, 60-foot multi-conductor cables that were draped all around Gammasphere. Detector slope boxes were connected directly to an entirely separate system called the VXI system, which would convert the signals to digitizer-readable differential signals before sending them off to "VXI digitizers". The VXI system had an entire "shack" designated to it, whereas the collector box upgrade can now be attached directly to Gammasphere's chassis and contain the DAQ system near the detectors. The previous system took up physical space within the room and presented a heat issue as well as multiple obsolescence risks and possibilities of power supply failure. The collector box eliminates these risks, and physically and digitally optimizes the overall system.

Collector Box Hardware

Throughout Gammasphere

Figure 2. A top-view mapping of Gammasphere's collector box setup.

Figure 1 shows a hemisphere of Gammasphere, and two of the collector boxes placed on it. On the other side of Gammasphere, there are another two collector boxes with the rest of the DAQ (the full picture is displayed on the DAQ system page). This is because Gammasphere has four pairs of collector boxes and VME crates (along with the power supply), each of which power and receive data from approximately 30 detectors. Figure 2 shows all of this from an above point of view; an "unfolded” drawing of how this mapping looks when viewing collectors and VME crates from their “active sides” where connections happen. Each collector box is shown (in the diagram) from the connector side, where cables are plugged in from the collector box to each SBX for power output. The output is accomplished using the same cable interfaces as used for the analog signal path, slow control-and-monitoring and all other detector functionality. All four collector boxes of Gammasphere are paired with their VME crate from their "active side", where the arrangement of digitizers, IOCs, and trigger modules are carefully placed. The collector boxes are labeled with the “GS#” they appear as in EPICS, with even “GS” numbers on the south hemisphere and odd “GS” numbers on the northern hemisphere. The semicircle “N” in Figure 2 represents the Gammasphere’s northern hemisphere, while “S” represents Gammasphere’s southern hemisphere. The compass directions in purple (NE, NW, SE, SW) are as in the current in-front-of-AGFA position. The collector boxes and VME crates are flipped right-to-left when comparing East versus West because the collector boxes are rotated 180 degrees in the birds’ eye view. Note that Figure 2 is giving a closeup of the system, but Figure 1 represents what the DAQ system actually looks like in real life. Although not shown in the Figure 2 diagram, each collector box also provides a connection for hooking up the alarm and status outputs from the external 48V DC supply, so that the collector can make that data available to the control system via EPICS.

In Each Collector Box

Figure 3. Collector box hardware