Image:GammasphereDAQupgrade.jpg|500px|thumb|DAQ System circled in red; one rack for each of the four "hemispheres" of Gammasphere | Image:GammasphereDAQupgrade.jpg|500px|thumb|DAQ System circled in red; one rack for each of the four "hemispheres" of Gammasphere | ||
</imagemap> | </imagemap> | ||
Gammasphere's DAQ system (data acquisition system) is now placed on relay racks by each of its "hemispheres". | Gammasphere's DAQ system (data acquisition system) is now placed on relay racks by each of its four "hemispheres". Each of the racks for the DAQ consists of a power supply, a [[Collector Box|collector box]], and a [[VME Crates|VME crate]] The data acquisition system observes, interprets, and modifies data taken from [[Gammasphere]] and appropriately presents it to the user. | ||
When Gammasphere collects data, single-ended signals are first collected from the slope box for the Ge Center, Ge Sides, and BGO segment. The signals are converted to differential signals by the SBX, and are then sent to the collector box so the signals can properly be routed to the digitizers. The digitizers process and output the desired information to the user based upon their data specifications. | |||
==DAQ System Function== | ==DAQ System Function== | ||
The DAQ system prior to upgrades consisted of VME crates, IOC Modules, Digitizers and Trigger Modules. There were two types of Digitizers (Master and Slave) and well as Trigger (Master and Router). | The DAQ system prior to upgrades consisted of VME crates, IOC Modules, Digitizers and Trigger Modules. There were two types of Digitizers (Master and Slave) and well as Trigger (Master and Router). |
Revision as of 16:34, February 10, 2023
Gammasphere's DAQ system (data acquisition system) is now placed on relay racks by each of its four "hemispheres". Each of the racks for the DAQ consists of a power supply, a collector box, and a VME crate The data acquisition system observes, interprets, and modifies data taken from Gammasphere and appropriately presents it to the user.
When Gammasphere collects data, single-ended signals are first collected from the slope box for the Ge Center, Ge Sides, and BGO segment. The signals are converted to differential signals by the SBX, and are then sent to the collector box so the signals can properly be routed to the digitizers. The digitizers process and output the desired information to the user based upon their data specifications.
DAQ System Function
The DAQ system prior to upgrades consisted of VME crates, IOC Modules, Digitizers and Trigger Modules. There were two types of Digitizers (Master and Slave) and well as Trigger (Master and Router).
DGS Commander EPICS Screens
This section contains an image map of DGS Commander and all subsequent EPICS screens
Go back to Digital Gammasphere Upgrade Project