Post-Processing Results: Difference between revisions
Jump to navigation
Jump to search
(Created page with "== Binary Files == SAS4A/SASSYS-1 generates and uses a number of binary files containing a wealth of information about the simulation. The number and types of files generated de…") |
m (Updated names of RESTART files.) |
||
(One intermediate revision by the same user not shown) | |||
Line 3: | Line 3: | ||
SAS4A/SASSYS-1 generates and uses a number of binary files containing a wealth of information about the simulation. The number and types of files generated depends on user input. | SAS4A/SASSYS-1 generates and uses a number of binary files containing a wealth of information about the simulation. The number and types of files generated depends on user input. | ||
;RESTART File ( | ;RESTART File (RESTART.dat) — ''output'' : The RESTART file contains all of the data needed to continue a calculation from where it left off. RESTART files are saved at the end of steady-state initialization and after every NSTEP main time steps. If NSTEP is zero, no restart files are saved. | ||
;RESTART File ( | ;RESTART File (RESTART.bin) — ''input'' : An ''input'' RESTART file must be provided if a simulation is being restarted from a previously saved state. In this case, the saved RESTART file must be renamed from <tt>RESTART.dat</tt> to <tt>RESTART.bin</tt> and an appropriate restart input file must be provided on standard input. |
Latest revision as of 16:38, June 16, 2016
Binary Files
SAS4A/SASSYS-1 generates and uses a number of binary files containing a wealth of information about the simulation. The number and types of files generated depends on user input.
- RESTART File (RESTART.dat) — output
- The RESTART file contains all of the data needed to continue a calculation from where it left off. RESTART files are saved at the end of steady-state initialization and after every NSTEP main time steps. If NSTEP is zero, no restart files are saved.
- RESTART File (RESTART.bin) — input
- An input RESTART file must be provided if a simulation is being restarted from a previously saved state. In this case, the saved RESTART file must be renamed from RESTART.dat to RESTART.bin and an appropriate restart input file must be provided on standard input.