Master

From GammaSphere DAQ
Revision as of 17:17, March 21, 2023 by Amujahid (talk | contribs)
Jump to navigation Jump to search

This screen gives controls and monitoring for the Master trigger of the DAQ system. The master trigger implements 11 bi-directional communications links. Each link (named A,B,C,D,E,F,G,H,L,R,U) is capable of transmitting data at 1Gbit/sec while simultaneously receiving data at 1Gbit/sec. The system connectivity is hierarchical. The master trigger communicates with router trigger modules within its detector system via links A-H, a master trigger module of another detector system via either link L or link R, and a MyRIAD module of another detector system via link U. The master trigger continuously transmits information to every module.

  • Section 1 of the screen inside red box is for LED Control.
  • Section 2 of the screen inside orange box is for miscellaneous statistics.
  • Section 3 of the screen inside yellow box contain miscellaneous controls.
  • Section 4 of the screen inside green box is for LRU Control. It handles the "L", "R", and "U" links for communication with other systems.
  • Section 5 of the screen inside blue box is for trigger selections.
  • Section 6 of the screen inside purple box is for propgation frames.
  • Section 7 of the screen inside pink box is for input link masks.
  • Section 8 of the screen inside gold box is for trigger rates.
  • Section 9 of the screen inside gray box is for veto selects.
  • Section 10 of the screen inside black box is for trigger settings.
Master Trigger CPLD ScreenSerDes ScreenMaster Trigger Wheel Maps OptionsWheel RAM Control ScreenMaster Trigger Diagnostics ScreenMasterTriggerFigure.png
About this image

Go back to Trigger Options