Detector Signals: Difference between revisions

From GammaSphere DAQ
Jump to navigation Jump to search
No edit summary
Line 6: Line 6:
GeSides are another contact point of the germanium. They entail the germanium around the hole in the center. There are two types of germanium placed in the detector: segmented and non-segmented. Segmented germanium has an insulator in the middle of its cylindrical shape (thus making two sides or halves), while non-segmented germanium is not split by anything. The two types of detectors are not treated very differently, but based on the type of germanium there are varying electronics used to receive data.  
GeSides are another contact point of the germanium. They entail the germanium around the hole in the center. There are two types of germanium placed in the detector: segmented and non-segmented. Segmented germanium has an insulator in the middle of its cylindrical shape (thus making two sides or halves), while non-segmented germanium is not split by anything. The two types of detectors are not treated very differently, but based on the type of germanium there are varying electronics used to receive data.  
==BGOSum==
==BGOSum==
In addition to [[High Purity Germanium (HPGe)|HPGe]], Gammasphere's detectors use BGO, or bismuth germanium oxide to absorb gamma-rays. The BGO surrounds each Gammasphere detector in a hexagonal shape. The BGO sum signal is the sum of hits to the sides of a detector's BGO.
==BGOPattern==
==BGOPattern==
==Electric Honeycomb==
==Electric Honeycomb==

Revision as of 21:34, February 13, 2023

Gammasphere detectors give data back through specific signals. The main signals are called GeCenter, GeSides, BGOSum, and now, after upgrades, BGOPatterns. These signals are defined by the way gamma-rays hit different parts of the HPGe inside a detector. The different points where the HPGe can be hit are called "contact points".

GeCenter

The germanium inside each detector is a cylindrical shape with a hole through its center. It becomes a contact point known as the "GeCenter".

GeSides

GeSides are another contact point of the germanium. They entail the germanium around the hole in the center. There are two types of germanium placed in the detector: segmented and non-segmented. Segmented germanium has an insulator in the middle of its cylindrical shape (thus making two sides or halves), while non-segmented germanium is not split by anything. The two types of detectors are not treated very differently, but based on the type of germanium there are varying electronics used to receive data.

BGOSum

In addition to HPGe, Gammasphere's detectors use BGO, or bismuth germanium oxide to absorb gamma-rays. The BGO surrounds each Gammasphere detector in a hexagonal shape. The BGO sum signal is the sum of hits to the sides of a detector's BGO.

BGOPattern

Electric Honeycomb