Master: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
This screen gives controls and monitoring for the Master [[Triggers|trigger]] of the [[DAQ system]]. The master trigger implements 11 bi-directional communications links. Each link (named A,B,C,D,E,F,G,H,L,R,U) is capable of transmitting data at 1Gbit/sec while simultaneously receiving data at 1Gbit/sec. The system connectivity is hierarchical. The master trigger communicates with router trigger modules within its detector system via links A-H, a master trigger module of another detector system via either link L or link R, and a MyRIAD module of another detector system via link U. The master trigger continuously transmits information to every module. | This screen gives controls and monitoring for the Master [[Triggers|trigger]] of the [[DAQ system]]. The master trigger implements 11 bi-directional communications links. Each link (named A,B,C,D,E,F,G,H,L,R,U) is capable of transmitting data at 1Gbit/sec while simultaneously receiving data at 1Gbit/sec. The system connectivity is hierarchical. The master trigger communicates with router trigger modules within its detector system via links A-H, a master trigger module of another detector system via either link L or link R, and a MyRIAD module of another detector system via link U. The master trigger continuously transmits information to every module. | ||
[[File:MasterTriggerFigure.png|800px|center]] | |||
<imagemap> | <imagemap> | ||
Image:MasterTrigger.png|800px|center | Image:MasterTrigger.png|800px|center | ||
Line 8: | Line 9: | ||
rect 849 452 978 473 [[Master Trigger Diagnostics Screen]] | rect 849 452 978 473 [[Master Trigger Diagnostics Screen]] | ||
</imagemap> | </imagemap> | ||
''Go back to [[Trigger Options]]'' | ''Go back to [[Trigger Options]]'' |
Revision as of 17:02, March 21, 2023
This screen gives controls and monitoring for the Master trigger of the DAQ system. The master trigger implements 11 bi-directional communications links. Each link (named A,B,C,D,E,F,G,H,L,R,U) is capable of transmitting data at 1Gbit/sec while simultaneously receiving data at 1Gbit/sec. The system connectivity is hierarchical. The master trigger communicates with router trigger modules within its detector system via links A-H, a master trigger module of another detector system via either link L or link R, and a MyRIAD module of another detector system via link U. The master trigger continuously transmits information to every module.
Go back to Trigger Options