Beamline Alignment Quick Reference: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 53: | Line 53: | ||
'''4) Scan DCM Bragg:''' | '''4) Scan DCM Bragg:''' | ||
[[Category:XMG]][[Category:Controls]][[Category:Beamline]] |
Revision as of 17:29, April 14, 2009
Back to X-Ray Microscopy
1) Scan mirror piezo:
Set slits to
Slit | H Size (um) | V Size (um) |
PBS | 2 | 2 |
NES | 2 | 2 |
BDA | 0.025 | - |
and scan mirror piezo +/- 1 V. Set mirror piezo to the maximum.
2) Scan DCM roll:
Set slits to
Slit | H Size (um) | V Size (um) |
PBS | 0.2 | 2 |
NES | 0.2 | 2 |
BDA | 0.025 | - |
and scan roll +/- 0.25 mrad. Set roll to maximum, but correct for back lash.
3) Scan DCM pitch:
Set slits to
Slit | H Size (um) | V Size (um) |
PBS | 2 | 2 |
NES | 2 | 2 |
BDA | 0.025 | - |
and scan pitch +/- 0.05 mrad. Set pitch to max.
4) Scan DCM Bragg: