<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.anl.gov/wiki_cnm/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Tzhou</id>
	<title>CNM Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.anl.gov/wiki_cnm/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Tzhou"/>
	<link rel="alternate" type="text/html" href="https://wiki.anl.gov/cnm/Special:Contributions/Tzhou"/>
	<updated>2026-06-04T03:16:25Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.43.8</generator>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=X-Ray_Microscopy&amp;diff=7373</id>
		<title>X-Ray Microscopy</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=X-Ray_Microscopy&amp;diff=7373"/>
		<updated>2025-01-14T18:55:30Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{X-ray Header}}&lt;br /&gt;
==Experiments==&lt;br /&gt;
*[[Diffraction]]&lt;br /&gt;
*[[Fluorescence]]&lt;br /&gt;
*[[Tomography]]&lt;br /&gt;
&lt;br /&gt;
==Beamline==&lt;br /&gt;
*[[Nanoprobe Scanning Quick Reference]]&lt;br /&gt;
*[[Beamline Instrumentation]]&lt;br /&gt;
*[[Beamline Controls]]&lt;br /&gt;
*[[Beamline Alignment Quick Reference]]&lt;br /&gt;
*[[Nanoprobe Optics Information]]&lt;br /&gt;
&lt;br /&gt;
==Multilayer Laue Lenses==&lt;br /&gt;
*[[The MLL Project]]&lt;br /&gt;
&lt;br /&gt;
[[Category:XMG]]&lt;br /&gt;
[[Category:Fluorescence]]&lt;br /&gt;
[[Category:Diffraction]]&lt;br /&gt;
[[Category:Tomography]]&lt;br /&gt;
[[Category:Controls]]&lt;br /&gt;
[[Category:Beamline]]&lt;br /&gt;
[[Category:MLL]]&lt;br /&gt;
&lt;br /&gt;
==New Capabilities==&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7052</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7052"/>
		<updated>2021-10-18T18:06:22Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: /* Main interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Get the latest version at home==&lt;br /&gt;
Go to &#039;&#039;&#039;https://hub.docker.com/r/danielzt12/dude&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
check out the latest version, and specify that when executing the &#039;&#039;&#039;docker run&#039;&#039;&#039; command.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Load data==&lt;br /&gt;
&#039;&#039;&#039;File -&amp;gt; Open&#039;&#039;&#039;, point to the mda folder and click &#039;&#039;&#039;OPEN&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
If you are using dude to look at data other than those acquired with the Eiger detector,  change that under &#039;&#039;&#039;Settings -&amp;gt; Detector&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Main interface==&lt;br /&gt;
[1] &#039;&#039;&#039;right mouse click&#039;&#039;&#039; on the canvas or drag while clicked, show the corresponding detector images. Also work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[2] when doing step [1], the motor positions and detector values are also updated , under &#039;&#039;&#039;P0&#039;&#039;&#039; (Point 0).&amp;lt;br&amp;gt;&lt;br /&gt;
[3] &#039;&#039;&#039;left mouse click&#039;&#039;&#039; on the canvas updates the position under &#039;&#039;&#039;P1&#039;&#039;&#039; (Point 1), and calculates the distance between P1 and P0. Does not work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[4] disable &#039;&#039;&#039;Auto&#039;&#039;&#039; to change the min and max of the color scale. The colormap can be changed under &#039;&#039;&#039;Settings&#039;&#039;&#039;. Toggle &#039;&#039;&#039;Log&#039;&#039;&#039; to switch between log and linear scale. Toggle &#039;&#039;&#039;Scale&#039;&#039;&#039; to show / hide the scale bar. The scaler bar is valid for the vertical axis only, and is only valid for the horizontal axis if the step size in x and y are equal.&amp;lt;br&amp;gt;&lt;br /&gt;
[5] drag while clicked with &#039;&#039;&#039;left mouse button&#039;&#039;&#039; to make a rectangle on the canvas to zoom in. &#039;&#039;&#039;Scroll&#039;&#039;&#039; up and down to change the zoom. &#039;&#039;&#039;drag&#039;&#039;&#039; when zoomed to pan.&amp;lt;br&amp;gt;&lt;br /&gt;
[6] click &#039;&#039;&#039;Full&#039;&#039;&#039; to reset zoom.&amp;lt;br&amp;gt;&lt;br /&gt;
[7] &#039;&#039;&#039;hover&#039;&#039;&#039; on the canvas will update the pixel position and intensity values. Show calibrated angles instead by enabling &amp;quot;Settings -&amp;gt; Show Angle&amp;quot;. This is only valid for &#039;&#039;&#039;eiger-in&#039;&#039;&#039; positions and if the angle calibration files are found under the &#039;&#039;&#039;Analysis&#039;&#039;&#039; folder. Disable and enable again if the calibration files have been changed.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[5] change here to show values from existing detector channels.&lt;br /&gt;
[]&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7051</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7051"/>
		<updated>2021-10-18T18:06:09Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: /* Main interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Get the latest version at home==&lt;br /&gt;
Go to &#039;&#039;&#039;https://hub.docker.com/r/danielzt12/dude&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
check out the latest version, and specify that when executing the &#039;&#039;&#039;docker run&#039;&#039;&#039; command.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Load data==&lt;br /&gt;
&#039;&#039;&#039;File -&amp;gt; Open&#039;&#039;&#039;, point to the mda folder and click &#039;&#039;&#039;OPEN&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
If you are using dude to look at data other than those acquired with the Eiger detector,  change that under &#039;&#039;&#039;Settings -&amp;gt; Detector&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Main interface==&lt;br /&gt;
[1] &#039;&#039;&#039;right mouse click&#039;&#039;&#039; on the canvas or drag while clicked, show the corresponding detector images. Also work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[2] when doing step [1], the motor positions and detector values are also updated , under &#039;&#039;&#039;P0&#039;&#039;&#039; (Point 0).&amp;lt;br&amp;gt;&lt;br /&gt;
[3] &#039;&#039;&#039;left mouse click&#039;&#039;&#039; on the canvas updates the position under &#039;&#039;&#039;P1&#039;&#039;&#039; (Point 1), and calculates the distance between P1 and P0. Does not work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[4] disable &#039;&#039;&#039;Auto&#039;&#039;&#039; to change the min and max of the color scale. The colormap can be changed under &#039;&#039;&#039;Settings&#039;&#039;&#039;. Toggle &#039;&#039;&#039;Log&#039;&#039;&#039; to switch between log and linear scale. Toggle &#039;&#039;&#039;Scale&#039;&#039;&#039; to show / hide the scale bar. The scaler bar is valid for the vertical axis only, and is only valid for the horizontal axis if the step size in x and y are equal.&amp;lt;br&amp;gt;&lt;br /&gt;
[5] drag while clicked with &#039;&#039;&#039;left mouse button&#039;&#039;&#039; to make a rectangle on the canvas to zoom in. &#039;&#039;&#039;Scroll&#039;&#039;&#039; up and down to change the zoom. &#039;&#039;&#039;drag&#039;&#039;&#039; when zoomed to pan.&amp;lt;br&amp;gt;&lt;br /&gt;
[6] click &amp;quot;Full&amp;quot; to reset zoom.&amp;lt;br&amp;gt;&lt;br /&gt;
[7] &#039;&#039;&#039;hover&#039;&#039;&#039; on the canvas will update the pixel position and intensity values. Show calibrated angles instead by enabling &amp;quot;Settings -&amp;gt; Show Angle&amp;quot;. This is only valid for &#039;&#039;&#039;eiger-in&#039;&#039;&#039; positions and if the angle calibration files are found under the &#039;&#039;&#039;Analysis&#039;&#039;&#039; folder. Disable and enable again if the calibration files have been changed.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[5] change here to show values from existing detector channels.&lt;br /&gt;
[]&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7050</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7050"/>
		<updated>2021-10-18T18:05:45Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: /* Main interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Get the latest version at home==&lt;br /&gt;
Go to &#039;&#039;&#039;https://hub.docker.com/r/danielzt12/dude&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
check out the latest version, and specify that when executing the &#039;&#039;&#039;docker run&#039;&#039;&#039; command.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Load data==&lt;br /&gt;
&#039;&#039;&#039;File -&amp;gt; Open&#039;&#039;&#039;, point to the mda folder and click &#039;&#039;&#039;OPEN&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
If you are using dude to look at data other than those acquired with the Eiger detector,  change that under &#039;&#039;&#039;Settings -&amp;gt; Detector&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Main interface==&lt;br /&gt;
[1] &#039;&#039;&#039;right mouse click&#039;&#039;&#039; on the canvas or drag while clicked, show the corresponding detector images. Also work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[2] when doing step [1], the motor positions and detector values are also updated , under &#039;&#039;&#039;P0&#039;&#039;&#039; (Point 0).&amp;lt;br&amp;gt;&lt;br /&gt;
[3] &#039;&#039;&#039;left mouse click&#039;&#039;&#039; on the canvas updates the position under &#039;&#039;&#039;P1&#039;&#039;&#039; (Point 1), and calculates the distance between P1 and P0. Does not work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[4] disable &#039;&#039;&#039;Auto&#039;&#039;&#039; to change the min and max of the color scale. The colormap can be changed under &#039;&#039;&#039;Settings&#039;&#039;&#039;. Toggle &#039;&#039;&#039;Log&#039;&#039;&#039; to switch between log and linear scale. Toggle &#039;&#039;&#039;Scale&#039;&#039;&#039; to show / hide the scale bar. The scaler bar is valid for the vertical axis only, and is only valid for the horizontal axis if the step size in x and y are equal.&amp;lt;br&amp;gt;&lt;br /&gt;
[5] drag while clicked with &#039;&#039;&#039;left mouse button&#039;&#039;&#039; to make a rectangle on the canvas to zoom in. &#039;&#039;&#039;Scroll up and down&#039;&#039;&#039; to change the zoom. &#039;&#039;&#039;drag&#039;&#039;&#039; when zoomed to pan.&amp;lt;br&amp;gt;&lt;br /&gt;
[6] click &amp;quot;Full&amp;quot; to reset zoom.&amp;lt;br&amp;gt;&lt;br /&gt;
[7] &#039;&#039;&#039;hover&#039;&#039;&#039; on the canvas will update the pixel position and intensity values. Show calibrated angles instead by enabling &amp;quot;Settings -&amp;gt; Show Angle&amp;quot;. This is only valid for &#039;&#039;&#039;eiger-in&#039;&#039;&#039; positions and if the angle calibration files are found under the &#039;&#039;&#039;Analysis&#039;&#039;&#039; folder. Disable and enable again if the calibration files have been changed.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[5] change here to show values from existing detector channels.&lt;br /&gt;
[]&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7049</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7049"/>
		<updated>2021-10-18T17:58:23Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: /* Main interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Get the latest version at home==&lt;br /&gt;
Go to &#039;&#039;&#039;https://hub.docker.com/r/danielzt12/dude&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
check out the latest version, and specify that when executing the &#039;&#039;&#039;docker run&#039;&#039;&#039; command.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Load data==&lt;br /&gt;
&#039;&#039;&#039;File -&amp;gt; Open&#039;&#039;&#039;, point to the mda folder and click &#039;&#039;&#039;OPEN&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
If you are using dude to look at data other than those acquired with the Eiger detector,  change that under &#039;&#039;&#039;Settings -&amp;gt; Detector&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Main interface==&lt;br /&gt;
[1] &#039;&#039;&#039;right mouse click&#039;&#039;&#039; on the canvas or drag while clicked, show the corresponding detector images. Also work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[2] when doing step [1], the motor positions and detector values are also updated , under &#039;&#039;&#039;P0&#039;&#039;&#039; (Point 0).&amp;lt;br&amp;gt;&lt;br /&gt;
[3] &#039;&#039;&#039;left mouse click&#039;&#039;&#039; on the canvas updates the position under &#039;&#039;&#039;P1&#039;&#039;&#039; (Point 1), and calculates the distance between P1 and P0. Does not work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[4] disable &#039;&#039;&#039;Auto&#039;&#039;&#039; to change the min and max of the color scale. The colormap can be changed under &#039;&#039;&#039;Settings&#039;&#039;&#039;. Toggle &#039;&#039;&#039;Log&#039;&#039;&#039; to switch between log and linear scale. Toggle &#039;&#039;&#039;Scale&#039;&#039;&#039; to show / hide the scale bar. The scaler bar is valid for the vertical axis only, and is only valid for the horizontal axis if the step size in x and y are equal.&amp;lt;br&amp;gt;&lt;br /&gt;
[5]&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7048</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7048"/>
		<updated>2021-10-18T17:55:11Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: /* Main interface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Get the latest version at home==&lt;br /&gt;
Go to &#039;&#039;&#039;https://hub.docker.com/r/danielzt12/dude&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
check out the latest version, and specify that when executing the &#039;&#039;&#039;docker run&#039;&#039;&#039; command.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Load data==&lt;br /&gt;
&#039;&#039;&#039;File -&amp;gt; Open&#039;&#039;&#039;, point to the mda folder and click &#039;&#039;&#039;OPEN&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
If you are using dude to look at data other than those acquired with the Eiger detector,  change that under &#039;&#039;&#039;Settings -&amp;gt; Detector&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Main interface==&lt;br /&gt;
[1] &#039;&#039;&#039;right mouse click&#039;&#039;&#039; on the canvas or drag while clicked, show the corresponding detector images. Also work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[2] when doing step [1], the motor positions and detector values are also updated , under &#039;&#039;&#039;P0&#039;&#039;&#039; (Point 0).&amp;lt;br&amp;gt;&lt;br /&gt;
[3] &#039;&#039;&#039;left mouse click&#039;&#039;&#039; on the canvas updates the position under &#039;&#039;&#039;P1&#039;&#039;&#039; (Point 1), and calculates the distance between P1 and P0. Does not work for 1D scans.&amp;lt;br&amp;gt;&lt;br /&gt;
[4] disable Auto&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7047</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7047"/>
		<updated>2021-10-18T17:46:45Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Get the latest version at home==&lt;br /&gt;
Go to &#039;&#039;&#039;https://hub.docker.com/r/danielzt12/dude&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
check out the latest version, and specify that when executing the &#039;&#039;&#039;docker run&#039;&#039;&#039; command.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Load data==&lt;br /&gt;
&#039;&#039;&#039;File -&amp;gt; Open&#039;&#039;&#039;, point to the mda folder and click &#039;&#039;&#039;OPEN&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
If you are using dude to look at data other than those acquired with the Eiger detector,  change that under &#039;&#039;&#039;Settings -&amp;gt; Detector&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Main interface==&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7046</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7046"/>
		<updated>2021-10-18T17:44:16Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;===Get the latest version at home===&lt;br /&gt;
Go to &#039;&#039;&#039;https://hub.docker.com/r/danielzt12/dude&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
check out the latest version, and specify that when executing the &#039;&#039;&#039;docker run&#039;&#039;&#039; command.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
===Load data===&lt;br /&gt;
&#039;&#039;&#039;File -&amp;gt; Open&#039;&#039;&#039;, point to the mda folder and click &#039;&#039;&#039;OPEN&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
If you are using dude to look at data other than those acquired with the Eiger detector,  change that under &#039;&#039;&#039;Settings -&amp;gt; Detector&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
===Main interface===&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7045</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7045"/>
		<updated>2021-10-18T17:42:13Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: /* Get the latest version */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;===Get the latest version at home===&lt;br /&gt;
Go to &#039;&#039;&#039;https://hub.docker.com/r/danielzt12/dude&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
check out the latest version, and specify that when executing the &#039;&#039;&#039;docker run&#039;&#039;&#039; command.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
===Load data===&lt;br /&gt;
&#039;&#039;&#039;File -&amp;gt; Open&#039;&#039;&#039;, point to the mda folder and click &#039;&#039;&#039;OPEN&#039;&#039;&#039;.&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7044</id>
		<title>Nanoprobe Scanning Quick Reference/dude</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Nanoprobe_Scanning_Quick_Reference/dude&amp;diff=7044"/>
		<updated>2021-10-18T17:37:51Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: Created page with &amp;quot;===Get the latest version===&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;===Get the latest version===&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
	<entry>
		<id>https://wiki.anl.gov/wiki_cnm/index.php?title=Sandbox/News&amp;diff=6953</id>
		<title>Sandbox/News</title>
		<link rel="alternate" type="text/html" href="https://wiki.anl.gov/wiki_cnm/index.php?title=Sandbox/News&amp;diff=6953"/>
		<updated>2021-08-31T21:21:49Z</updated>

		<summary type="html">&lt;p&gt;Tzhou: Created page with &amp;quot;# 2021R1  # 2021R2  # 2021R3&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;# 2021R1&lt;br /&gt;
&lt;br /&gt;
# 2021R2&lt;br /&gt;
&lt;br /&gt;
# 2021R3&lt;/div&gt;</summary>
		<author><name>Tzhou</name></author>
	</entry>
</feed>